LASER VIBROMETRY · PVM-LDV-300

Laser Doppler vibrometer | Laser Doppler vibrometry

Laser Doppler vibrometer features a portable integrated design, a wide measurement frequency range, and picometer-level resolution. Customized services are available to meet customer requirements.

laser vibrometer

Capabilities and Intended Tasks

The following information supports preliminary system discussions. Final performance and interfaces depend on the selected configuration and technical agreement.

Application-specific integration

Hardware and software combinations are configured around the measurement objective.

Multi-parameter sensing

Ranging, temperature and industrial vision can be integrated when required.

Focus and height assistance

Height feedback can assist focusing where standard autofocus response is insufficient.

Integrated RGB 3D vision camera

Depth and visual tracking capabilities, equipped with a manually controlled pan-tilt head, and capable of area-scan vibration measurement.

Typical Applications

  • Portable integrated design
  • Laser Doppler principle
  • DC-100kHz frequency range
  • Pm level resolution
  • 0.35-30 m working distance (custom close-range lens available)
  • Multi-modal testing scenarios
  • Synchronized multi-channel monitoring
  • Customized integrated non-contact measurement
PVM-LDV-300 Laser Doppler Vibrometer | VIPICO

PVM-LDV-300

Laser Doppler Vibrometer

An integrated optical interferometer and signal-processing unit for industrial inspection robots, UAVs, vibration shakers, and online equipment monitoring, providing long-range, non-contact vibration measurement.

Non-contact vibration measurementSimultaneous digital / analog outputAmbient-light interference resistanceLow-power integration
VIPICO PVM-LDV-300 Laser Doppler Vibrometer
0.35-30 m (custom close-range lens available)Measurement distance
DC-100 kHzMaximum vibration frequency range
±3 m/sMaximum velocity range

FEATURES

Features & Applications

The compact aluminum-alloy housing is designed for equipment and platform integration and optimized for industrial lighting conditions.

01

Portable Design

An all-in-one design based on laser Doppler technology, suitable for outdoor testing.

02

Long-Range Red Aiming Beam

0.35-30 m measurement distance with an adjustable-brightness red aiming beam; custom close-range lenses are available.

03

Dual Synchronous Outputs

Simultaneous digital and analog signal outputs with sampling rates up to 600 kHz.

04

Low-Power Integration

DC 12 V power supply and power consumption below 5 W for easy platform integration.

05

Environmental Adaptability

A field-optimized anti-speckle algorithm improves resistance to ambient-light interference.

Application AreaTypical Measurement Objects & Tasks
Platform IntegrationIndustrial inspection robots, UAVs, and vibration shaker systems
Power & Chemical IndustriesVibration measurement of power equipment and lines, chemical equipment, pumps, and piping
Appliances & MachineryVibration testing of major appliances and compressors; machinery fault-diagnosis measurements
Structures & EnvironmentStructural health monitoring of bridges, dams, and buildings; factory environmental-vibration assessment

SPECIFICATIONS

Technical Specifications

The 30 kHz and 100 kHz configurations retain their respective measurement ranges; both provide non-contact vibration measurement.

Model
PVM-LDV-300
Measurement Distance
0.35-30 m (custom close-range lens available)
Vibration Frequency Range
DC-30 / DC-100 kHz
Sampling Rate
Up to 600 kHz
Velocity Range
Up to ±3 m/s
Amplitude Linearity Error
< 1%
Velocity Resolution
< 1 μm/s @ 1000 Hz
Displacement Resolution
< 0.1 nm @ 1000 Hz
Measurement / Visible Laser
1550 nm / 633 nm red
Measurement Laser Output
< 10 mW, CLASS 1*
Ambient-Light Immunity
> 60000 lux
Operating Temperature
0-50 °C
Protection / Housing
IP63 / aluminum alloy
Power Supply / Consumption
DC 12 V / < 5 W
Digital Output
1000Base-T Ethernet
Analog Output
BNC (5 V)
Dimensions
135 × 80 × 60 mm
Weight
0.9 kg

* The laser safety classification follows the source documentation. Applicability after changes to the measurement wavelength or optical configuration is subject to the final product laser-safety assessment. Higher resolution is available upon request.

ConfigurationMaximum VelocityAmplitude Linearity ErrorFrequency Range
30 kHz configuration1.5 m/s< 1%DC-30 kHz
100 kHz configuration3 m/s< 1%DC-100 kHz

PRODUCT VIEWS

Product Views

Front, side, and top views of the instrument.

PVM-LDV-300 front, side, and top views

ACCESSORIES

Accessories & Expansion Options

Accessories can be selected according to field measurement, automation integration, and data-acquisition requirements. The final scope of supply is subject to technical confirmation.

Autofocus Linear Stage

±200 mm travel

Industrial Camera Integration

Customizable camera specifications

Binocular Structured-Light Camera

0.1-4 mm depth accuracy @ 1 m; customization available

Data Acquisition Card

256 kHz default sampling rate, 4 channels

Pan-Tilt Tripod

Manually adjustable pan-tilt head; ODS post-processing software included

Other Custom Services

Contact our sales and technical support teams

CUSTOMER SERVICE

Pre-sales & After-sales Service

Professional support is available throughout consultation, delivery, operation, and training.

Technical Consultation

Professional pre-sales technical consultation based on your application and measurement requirements.

Remote Demonstration

Remote product and operation demonstrations are available before purchase.

One-year Warranty & Lifetime Repair Support

A one-year quality warranty is included. After the first year, products with quality issues may be returned to the original factory for lifetime repair support.

Calibration Certificate

Each instrument is supplied with a calibration certificate issued by a recognized authoritative institution.

Complimentary Remote Training

One complimentary remote operation training session is included.

On-site Training

Paid on-site operation and application training is also available.

CALIBRATION EXCERPT

Calibration Summary

Certificate No. LSvm2024-08701. Refer to the original certificate for complete calibration conditions, traceability information, and the applicable instrument.

-0.48% to 0.40%Indication-error range at the listed 5 Hz-20 kHz test points
5 Hz-20 kHzFrequency-response table range shown in the manual
PVM-LDV-300 calibration certificate excerpt showing amplitude linearity results
PVM-LDV-300 calibration certificate excerpt showing frequency-response results

Sales & Technical Support

For accessory compatibility, interface options, and customized solutions, contact Beijing VIPICO Optoelectronic Technology Co., Ltd.

VIPICO | PVM-LDV-300 Laser Doppler VibrometerDocument Version: V1.1 · 2026.09

Public Configuration Information

Configuration item Current public information Notes
Model PVM-LDV-300 Current published model.
Product type  laser Doppler vibrometer Supports task-specific hardware and software combinations.
Measurement method Non-contact laser vibration measurement For objects where contact sensors are unsuitable.
Optional integrations Ranging, temperature and industrial vision Availability and interfaces are defined by project agreement.
Assisted functions Height feedback and autofocus assistance Implementation depends on selected modules and site conditions.
Typical tasks Multi-modal, multi-parameter and customized non-contact measurement Selection depends on object, distance, frequency band and accuracy.
Numerical specifications Defined by formal technical documentation or project agreement The webpage does not replace the final configuration list.

 

Define the object, distance, frequency range and required output.

Application paths include Industrial Equipment, Research & Laboratory Testing and Ultrasonics. See Technology and Resources for measurement principles and error control.

Scroll to Top